Evgeny 373b80ddcb fix merkle_sync: prefix serialization writes LSB bytes instead of MSB
_prefix_write was writing the least significant pb bytes of the 64-bit
prefix, but the protocol expects the most significant pb bytes (bits
63..64-pb*8). For pb<=4 these ranges are disjoint → wire always got
zeros. _prefix_read also lacked the final left-shift to align the
result at bit 63.

This caused all level>=2 merkle sync requests/batches to receive
prefix=0 instead of the real prefix, making get_items/update_bucket_hash
find zero members → handle_batch len=7 with no data → sync completed
without actually exchanging member data.